Glass Gas Discharge Tube – RLM102 Series

Glass Gas Discharge Tube – RLM102 Series

Short Description:

ROHS compliant

Bilateral symmetrical

Less decay at on/off state

Approximately zero leaking current before clamping voltage

High capability to withstand repeated lightning strikes

Low electrode capacitance ( 1.0pF ) and high isolation (100MΩ)

Temperature, humidity and lightness insensitive

Working temperature range: -45 ~ + 85

Storaging temperature range: -45 ~ + 85


Product Detail

Product Tags

Applications

Power Supplies
Satellite antenna
Motor sparks eliminating
Radio amplifiers
Relay switching spark absorbing
Alarm systems
Data line pulse guarding
Cathode ray tubes in Monitors/Television Viewing
Telephone/Fax/ModemSystems
High frequency signal transmitters/ eceivers

Product Name

Product Name

Electrlcal Characterlstlcs

Type Number

DC Spark-Over Voltage

Min. Insulation Resistance

Max.

Capacitance (1kHz-6Vmax.)

Surge Current Capacity

Surge Life Test @8/20ɥs

Vs

Test Voltage

IR

Cj

8/20ɥs

V

V

MΩ

pF

A

RLM102-141N

140(126~210)

50

100

1

1000

100A 10 times

RLM102-181N

180±30%

50

100

1

1000

100A10 times

RLM102-201M

200±20%

100

100

1

1000

100A10 times

RLM102-301M

300±20%

100

100

1

1000

100A10 times

RLM102-401M

400±20%

250

100

1

1000

100A10 times

RLM102-501M

500±20%

250

100

1

1000

100A10 times

Test Methods And Results

Test Item

Test Method

Specification

DC Spark-over Voltage Vs(V)

Measure starting discharge voltage (Vs) by gradually increasing applied DC voltage. Test current is 0.5mA max. And the DC voltage ascends up within 500V/second.

It depands on each spec.

Insulation Resistance

Measure the insulation resistance across the terminal at regular voltage. But the test voltage doesn't over the DC spark-over voltage.

100MΩ min.

Capacitance Cj(pF)

Measure the electrostatic capacitance by applying a voltage of less than 6V (at 1KHz) between terminals.

1pF max.

Life

10KV with 1500pf condenser is discharged through 0Q resistor. 200 times at an interval of 10sec.

DC spark-over voltage JSE: | △ Vs/Vs | ≤30%

Surge Current Capacity

1.2/50卩s & 8/20ps. 3000A, electrically connected with a resistor (4~6 Ω), ±5 times, each time interval 60 seconds. Thereafter outer appearance shall be visually examined.

No crack and no failures

Cold Resistance

Measurement after -40°C /1000 HRS & normal temperature/2 HRS.

Features are conformed to rated spec.

Heat Resistance

Measurement after 125°C /1000 HRS & normal temperature/2 HRS.

Humidity Resistance

Measurement after humidity 90*95 (45 C°C)/1000 HRS & normal temperature/2 HRS.

Temperature Cycle

10 times repetition of cycle -40 °C /30min→normal, temp/2 min→125°C /30min, measurement after normal temp/2 HRS.

Solder Ability

Apply flux and immerse in molten solder 230±5°C for 3sec up to the point of 1.5mm from body. Check for solder adhesion.

Lead wire is evenly covered by solder.

Solder Heat

Measurement after lead wire is dipped up to the point of 1.5mm from body into 260 ±5°C solder for 10sec.

Conformed to rated spec.

Recommended Soldering Conditions - Flow Soldering Conditions

Flow Soldering Conditions

Hand Soldering
Solder iron temperature: 350 ± 5 °C
Heating time: 3 seconds max

General attention to soldering
1. High soldering temperatures and long soldering times can causeleaching of the termination, decrease in adherence strength, andthe change of characteristic may occur.
2. For soldering , please refer to the soldering curves aboveHowever , please keep exposures to temperatures exceeding 200 Cto fewer than 50 seconds.
3. Please use a mild flux ( containing less than 0. 2wt % CI ). Also , ifthe flux is water soluble, be sure to wash thoroughly to remove anyresidue from the underside of components that could affectresistance.

1 ) Time shown in the above figures is measured from the point when chip surface reaches temperature.
2 ) Temperature difference in high temperature part should be within 110°C
3 ) After soldering , do not force cool , allow the parts to cool gradually.

Cleaning

When using ultrasonic cleaning , the board may resonate if the output power is too high . Since this vibration can cause cracking or a decreasein the adherence of the termination, we recommend that you use the conditions below.
Frequency: 40KHZ max.
Output power: 20W/liter
Cleaning time: 5 minutes max.

Dimensions

Dimensions

DIM

Millimeters

Inches

A

5.0±0.5

0.197±0.02

C

Φ2.6±O,5

0.102±0.02

D

Φ2.7+0.5

0.106±0.02

Taping and Reel Specifications

Taping and Reel Specifications

Symbol

Millimeters

Inches

W

12.0±0.2

0.472±0.008

PO

4.0+0.1

0.157±0.004

P1

4.0±0.1

0.157±0.004

P2

2.0+0.1

0.079+0.004

D

Φ1.5±0.1

0.059±0.004

d

Φ1.5±0.1

0.059+0.004

E

1.75±0.1

0.069±0.004

F

5.5±0.05

0.217+0.002

D1

178.0

7.007

D0

13.0

0.512

W1

15.0

0.591

Quantity: 1500PCS / inner box