China Gold Supplier for Uni-Directional Transorb - Surge Protection Devices – TP10D – Ruilongyuan

China Gold Supplier for Uni-Directional Transorb - Surge Protection Devices – TP10D – Ruilongyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for Polyswitch Resettable Fuse , 16v Resettable Fuse , Pptc Resettable Fuse , We are sincerely looking forward to establishing good cooperative relationships with customers from at home and abroad for creating a bright future together.
China Gold Supplier for Uni-Directional Transorb - Surge Protection Devices – TP10D – Ruilongyuan Detail:

Outdoor and Commercial

Wash wall lighting

LED Lighting

Parking garage/lot

Roadway lighting

lighting

Traffic lighting

Flood lighting

Digital signage

Tunnel lighting

Security power supply

Street lighting

1.UVT: It is an abbreviation of Ultra low voltage triggering technology. It is a design that absorb the high and low voltage energy of the surge in advance. It can absorb the surge energy more completely, and the residual voltage is low, and the protection effect on the back-end equipment is obvious. This technology is patented by Ruilongyuan.

2.Class I: In this paper, a luminaire that refers to “accessible conductive parts connected to protective earthing conductors in fixed wiring” (from IEC60598 – luminaires – general requirements and test – Chinese version).

3.Class II: In this paper, the term “light-protection protection is not only dependent on basic insulation, but also has additional safety measures, such as double insulation or reinforced insulation, but no protective grounding or protection measures depending on installation conditions” (from IEC60598-4.Luminaires – General Requirements and Tests – Chinese version).

4.Leakage current: In this paper, the current flowing through the SPD does not occur when the power is connected. For example, zinc oxide varistor is a device with leakage characteristics.

5.Freewheeling: Current from the connected power source that flows through the SPD during and after the discharge current passes. For example, gas discharge tubes and thyristors are devices with freewheeling characteristics (cited from IEC61643-11).

6.10kA: refers to the maximum discharge current (Imax) in the 8/20μs surge waveform test.

7.10kV: refers to the nominal discharge voltage (Vn) in the 1.2/50μs surge waveform test.

Specification

Test Standard: EN61643-11/ UL14494th

TP20D

Units

Electrical parameters

Rated operating voltage8

277

VAC

Max. Continuous voltage9

277

VAC

Cross-section area (Flexible)

1.3/16

mm2/AWG

Mounting on

Custom

 

Surge parameter

Norminal discharge current10(8/20μs) (In)

5

kA

Max. discharge current11 (8/20μs) (Imax)

10

 kA

Nominal discharge voltage12(1.2/50μs) (Vn)

10

kV

Maximum discharge voltage13(1.2/50μs) (Vmax)

20

kV

Voltage protection level14 (Up)

 

 

L-N/PE

950

V

N-PE

1600

V

Placement and transportation parameters

Enclosure material

ABS765A(94V0)

 

Operating temperature range

-40~80

Ingress Protection

IP65

 

Size

79.5×38.6×16.5

mm

Weight (One piece)

77(±3)

g

Package size

315×290×272

mm

Package quantity

150

pcs

8.Rated operating voltage: The normal AC mains voltage rating assigned by the manufacturer to the SPD (cited from Ul1449).

9.Max. Continuous voltage: The maximum rms voltage that can be continuously applied to the SPD (cited from IEC61643-11).

10.Nominal discharge current: The current peak selected by the manufacturer. With SPD, the current waveform is 8/20μs, and the SPD remains functional after 15 surges (from UL1449)

11.Maximum discharge current: The peak value of the SPD current flowing through the 8/20 waveform and the manufacturer’s claimed amplitude. Belongs to the T2 test type (quoted from IEC61643-11).

12.Nominal discharge voltage: The discharge open circuit voltage peak with a 1.2/50 μs waveform and flowing through the SPD (this parameter is the RUILON laboratory custom parameter, which is equivalent to the open circuit voltage Uoc defined by the T3 test in IEC61643-11).

13.Maximum discharge voltage: The peak value of the SPD voltage flowing through the 1.2/50 waveform and the manufacturer’s claimed amplitude (this parameter is the RUILON laboratory custom parameter, which is twice the open circuit voltage of the T3 test in IEC61643-11). (2Uoc)).

14.Voltage protection level: The maximum voltage expected to occur between the two ends of the SPD due to the application of a specified gradient of the impulse voltage and the specified amplitude and the inrush current of the waveform (cited from IEC61643-11).

Surge test characteristics of TP20D

Test

Surge

Strikess

Pulse Rating

(8/20μs)

10kA

1

8kA

2

5kA

15

3.75kA

45

2.5kA

200

TTF DATE

10kA

2

5kA

50

Nominal discharge voltage: 20kV, 1.2/50μs;

Maximum discharge current: 20kA, 8/20μs;

Executive standard: IEC/EN:61643-11/UL14494th;

Parallel SPD equipment;

UVT ultra-low voltage technology, more adequate protection;

With lead wire for easy connection;

Ultra-thin shape: 79.5  × 38.6  × 16.5, easy to reset;

IP65 waterproof and dustproof;

Installation of Class I and Class II lamps that meet the rated voltage of 110 to 277 VAC;

Excellent performance after TTF’s rigorous testing.

Certified by CB, UL, TUV and CE.

A variety of wiring methods are combined to meet string and parallel wiring requirements.

about uvt

Since the introduction of the 20kV ultra-thin surge suppressor in 2014, Ruilongyuan Electronics has continuously improved its surge protection technology and proposed the theoretical concept of efficient absorption of surge energy. After many tests, the circuit model was established and the ultra-low voltage triggering scheme (UVT1) was introduced. It was applied to the new totem surge suppressor, which greatly improved the surge protection efficiency and played a good role in the protected equipment. Surge protection effect.

Typical installation diagram

Notes:

1.The connection line of the lightning arrester will be  connected after tining.

2.If there are no wiring terminals, wires should be welded,and the welds need to do isolation treatment.

3.L—-Brown;  N—- Blue; P E—Yellow and Green.

Dimensions

Disclaimer Notice -

Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. RUILON products are not designed for, and may not be used in, all applications.


Product detail pictures:

China Gold Supplier for Uni-Directional Transorb - Surge Protection Devices – TP10D – Ruilongyuan detail pictures


Related Product Guide:

We constantly continually give you essentially the most conscientious client provider, plus the widest variety of designs and styles with finest materials. These initiatives include the availability of customized designs with speed and dispatch for China Gold Supplier for Uni-Directional Transorb - Surge Protection Devices – TP10D – Ruilongyuan , The product will supply to all over the world, such as: Juventus, Argentina, Montpellier, We always adhere to follow the honesty, mutual benefit, common development, after years of development and the tireless efforts of all staff, now has perfect export system, diversified logistics solutions, comprehensive meet customer shipping, air transport, international express and logistics services. Elaborate one-stop sourcing platform for our customers!
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Jerry from Juventus - 2017.12.19 11:10
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Rosalind from US - 2018.10.01 14:14
    Write your message here and send it to us